description: "### Home Automation Integration The ClimateControl module is designed for flexibility, offering native support for various platforms via MQTT and a HTTP REST API. - **Home Assistant:** Experience seamless \"plug-and-play\" integration using the built-in **Auto Discovery** feature. - **Homey**: Use…"
url: "https://protoart.net/knowledgebase/me_cn105_atw_wifi_http_mqtt/"
updated: "2026-07-03"
category: Mitsubishi Electric
---

# ME_CN105_ATW_WIFI – HTTP API & MQTT Topics

### Home Automation Integration

The ClimateControl module is designed for flexibility, offering native support for various platforms via MQTT and a HTTP REST API.

- **Home Assistant:** Experience seamless "plug-and-play" integration using the built-in **Auto Discovery** feature.
- **Homey**: Use the community developed ClimateControl app from the Homey app store.
- **Other systems:** The module is widely used with systems including Loxone, Nodered and other custom automation platforms. For these platforms, use either MQTT or HTTP REST API for communication.
-

---

#### MQTT Client

ClimateControl functions as a MQTT client and requires a connection to an MQTT broker (such as **Mosquitto**).

- **Compatibility:** Supports both **MQTT v5** and **v3.1.1**.
- **Setup:** Enter your broker's URL, port and credentials via the local web interface.
- **Security Note:** Secure MQTT (TLS/SSL) is currently not supported.
- **Topic Base:** /climacontrol/HVAC_XXXXXX
- **Retain**: topic retain flag is enabled

*Note: While alle possible commands are listed below, some might not be available on your unit.*

#### MQTT Command Reference

**Reading**
Settings and status can be read from the base topic + specific topic.
For example: /climacontrol/HVAC_XXXXXX/heatpump/power

**Writing**
Settings can be changed using the base topic + specific topic + set.
For example: /climacontrol/HVAC_XXXXXX/heatpumpt/power/set -> on

**Status / Sensors**

| Description | Value | Endpoint |
| --- | --- | --- |
| Restart ClimateControl | any value | `device/command/restart` |
| Zone 1 room temperature setpoint | float, 10–30°C | `heatpump/zone1/room_target_temperature/set` |
| Zone 2 room temperature setpoint | float, 10–30°C | `heatpump/zone2/room_target_temperature/set` |
| Zone 1 flow target temperature | float, 5–60°C | `heatpump/zone1/flow_target_temperature/set` |
| Zone 2 flow target temperature | float, 5–60°C | `heatpump/zone2/flow_target_temperature/set` |
| DHW (hot water) target temperature | float | `heatpump/dhw/flow_target_temperature/set` |
| DHW mode | normal, eco | `heatpump/dhw/mode/set` |
| DHW force (boost hot water now) | on, off | `heatpump/dhw/forced_active/set` |
| Holiday mode | on, off | `heatpump/holiday_mode/set` |
| Power | on, off | `heatpump/power/set` |
| Zone 1 operation mode | off HEAT_ROOM_TEMP HEAT_FLOW_TEMP HEAT_COMPENSATION_CURVE COOL_ROOM_TEMP COOL_FLOW_TEMP FLOOR_DRYUP | `heatpump/zone1/mode/set` |
| Zone 2 operation mode | same set as above | `heatpump/zone2/mode/set` |
| Prohibit DHW | on, off | `heatpump/prohibit/dhw/set` |
| Prohibit Zone 1 heating | on, off | `heatpump/prohibit/heating_zone1/set` |
| Prohibit Zone 1 cooling | on, off | `heatpump/prohibit/cooling_zone1/set` |
| Prohibit Zone 2 heating | on, off | `heatpump/prohibit/heating_zone2/set` |
| Prohibit Zone 2 cooling | on, off | `heatpump/prohibit/cooling_zone2/set` |
| Prohibit server control | on, off | `heatpump/prohibit/server_control/set` |

**Controls**

| Description | Value | Endpoint |
| --- | --- | --- |
| Controller date/time | string (`YYYY-MM-DD HH:MM:SS`) | `heatpump/controller_datetime` |
| Power | on, off | `heatpump/power` |
| Operating state | off, dhw_on, heat_on, cool_on, frost_protect, legionella_prevention | `heatpump/operation` |
| Holiday mode | on, off | `heatpump/holiday_mode` |
| Controller firmware version | integer | `heatpump/controller_version` |
| Fault code | string | `heatpump/fault_code` |
| Multizone status | integer | `heatpump/multizone_status` |
| Defrost active | true, false | `heatpump/defrost_active` |
| Compressor on | true, false | `heatpump/compressor_on` |
| Compressor frequency | Hz | `heatpump/compressor_frequency` |
| Heat source | integer (enum) | `heatpump/heat_source` |
| Output power | kW | `heatpump/output_power` |
| Indicative output power | kW | `heatpump/indicative_output_power` |
| Runtime | hours | `heatpump/runtime` |
| Primary flow rate | L/min | `heatpump/flowrate` |

**Temperatures & water circuit**

| Description | Value | Endpoint |
| --- | --- | --- |
| Outside air temperature | °C | `heatpump/outside_temperature` |
| Feed temperature | °C | `heatpump/feed_temperature` |
| Return temperature | °C | `heatpump/return_temperature` |
| Boiler flow temperature | °C | `heatpump/boiler_flow_temperature` |
| Boiler return temperature | °C | `heatpump/boiler_return_temperature` |
| Mixing tank temperature | °C | `heatpump/mixing_tank_temperature` |
| Max/min allowed flow temperature | °C | `heatpump/max_flow_temperature``heatpump/min_flow_temperature` |
| Refrigerant liquid / condensing temperature | °C | `heatpump/refrigerant_liquid_temperature` `heatpump/refrigerant_condensing_temperature` |
| Advanced refrigerant circuit diagnostics (discharge, suction, heat-sink, compressor surface, subcool, superheat temps) | °C | `heatpump/rcdischargeTemp` `heatpump/rcouliquidpipetemp` `heatpump/rcoutwoPhasepipetemp` `heatpump/rcousuctionpipetemp` `heatpump/rcouheatsinktemp` `heatpump/rcoucompressorsurfacetemp`  `heatpump/rcdischargesuperheattemp` `heatpump/rcsubcooltemp` |

**Actuators / inputs**

| Description | Value | Endpoint |
| --- | --- | --- |
| Water pump 1/2/3 active | true, false | `heatpump/waterpump_active` `heatpump/waterpump2_active` `heatpump/waterpump3_active` |
| Three-way valve 1/2 active | true, false | `heatpump/threeway_valve_activeheatpump/``threeway_valve2_active` |
| Mixing valve step / status | integer | `heatpump/mixing_valve_stepheatpump/``heatpump/mixing_valve_status` |
| Booster active | true, false | `heatpump/booster_active` |
| Immersion heater active | true, false | `heatpump/immersion_active` |
| IN1/IN5/IN6 thermostat request | true, false | `heatpump/in1_thermostat_requestheatpump/``in5_thermostat_requestheatpump/``in6_thermostat_request` |
| DIP switch positions (SW1–SW6) | binary string | `heatpump/dipswitch/sw1` … `sw6` |

**Zone 1 / Zone 2** (same set for each zone, `zone1`/`zone2`)

| Description | Value | Endpoint |
| --- | --- | --- |
| Room temperature | °C | `heatpump/zone{1,2}/room_temperature` |
| Room target temperature | °C | `heatpump/zone{1,2}/room_target_temperature` |
| Flow target temperature | °C | `heatpump/zone{1,2}/flow_target_temperature` |
| Feed / return temperature | °C | `heatpump/zone{1,2}/feed_temperature``heatpump/zone{1,2}/return_temperature` |
| Operation mode | HEAT_ROOM_TEMP HEAT_FLOW_TEMP HEAT_COMPENSATION_CURVE COOL_ROOM_TEMP COOL_FLOW_TEMP FLOOR_DRYUP | `heatpump/zone{1,2}/mode` |

**DHW (hot water)**

| Description | Value | Endpoint |
| --- | --- | --- |
| DHW temperature (primary/secondary) | °C | `heatpump/dhw/temperature``heatpump/dhw/temperature_secondary` |
| DHW target temperature | °C | `heatpump/dhw/flow_target_temperature` |
| Legionella prevention target temp | °C | `heatpump/dhw/legionella_prevention_target_temp` |
| Flow temperature drop | °C | `heatpump/dhw/flow_temperature_drop` |
| DHW mode | normal, eco | `heatpump/dhw/mode` |
| DHW force active | on, off | `heatpump/dhw/forced_active` |

**Prohibit flags & energy**

 

| Description | Value | Endpoint |
| --- | --- | --- |
| Prohibit DHW / Z1 heating / Z1 cooling / Z2 heating / Z2 cooling / server control | on, off | `heatpump/prohibit/dhw``heatpump/prohibit/heating_zone1``heatpump/prohibit/cooling_zone1``heatpump/prohibit/heating_zone2``heatpump/prohibit/cooling_zone2``heatpump/prohibit/server_control` |
| Energy consumed (heating/cooling/DHW) | kWh | `heatpump/energy/consumed_heatingheatpump/energy/``consumed_coolingheatpump/energy/``consumed_dhw` |
| Energy delivered (heating/cooling/DHW) | kWh | `heatpump/energy/delivered_heatingheatpump/energy/``delivered_coolingheatpump/energy/``delivered_dhw` |

#### HTTP REST API

For direct control and status monitoring, you can interface with the module via standard HTTP requests.

- **Status Inquiry:** Perform a `GET` request to: http://heatpump.local/control
- **Response:** Returns a JSON string containing module, heat pump, and sensor telemetry.

#### HTTP Command Reference

| Description | Value | Example |
| --- | --- | --- |
| Restart ClimateControl | no value needed | `?cmd=restart` |
| Room temperature setpoint | `zone:temperature` Zone is:  - `zone1` - `zone2` - `both` Temperature is: - float, 0–100 | `?cmd=heatpump&set_room_temperature=zone1:21.5` |
| Flow target temperature | `zone:temperature` zone is - `zone1` - `zone2` - `both` Temperature is: - float, 0–100 | `?cmd=heatpump&set_flow_target_temperature=zone1:45.0` |
| DHW (hot water) target temperature | float, 0–100 | `?cmd=heatpump&set_dhw_target_temperature=50.0` |
| DHW mode | `normal` `eco` | `?cmd=heatpump&set_dhw_mode=eco` |
| DHW force (boost hot water now) | `on` `off` | `?cmd=heatpump&set_dhw_force=on` |
| Holiday mode | `on` `off` | `?cmd=heatpump&set_holiday=off` |
| Power mode | `on` `off` (anything else → standby) | `?cmd=heatpump&set_power_mode=on` |
| Heatpump operating mode | `zone:mode`  Zone is: - `zone1` - `zone2` - `both` mode is: - `off` - `HEAT_ROOM_TEMP` - `HEAT_FLOW_TEMP` - `HEAT_COMPENSATION_CURVE` - `COOL_ROOM_TEMP` - `COOL_FLOW_TEMP` - `FLOOR_DRYUP` | `?cmd=heatpump&set_heatpump_mode=zone1:HEAT_ROOM_TEMP` |
| MRC mode | `disabled` `function` `temperature` `running_mode` `system_on_off` | `?cmd=heatpump&mrc_mode=disabled` |
| Controller mode flag | `flag:on/off` flag is:  - `forced_dhw` - `holiday_mode` - `prohibit_dhw` - `prohibit_zone1_heating` - `prohibit_zone1_cooling` - `prohibit_zone2_heating` - `prohibit_zone2_cooling` - `server_control` | `?cmd=heatpump&set_controller_mode=forced_dhw:on` |